Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use… Mehr…
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use are high reliability and numerous advantages offered by isolating them against ground. Insulation level is a decisive factor for networks operational reliability and safety. Insufficient insulation-to-ground resistance can cause various disturbances. Though ground faults in IT systems do not make networks operation impossible, they may cause severe problems with their safe functioning. In this book the most important issues concerning normal operation and ground fault phenomena are described in concise form. Numerous methods of insulation resistance and capacitance measurement in live circuits are presented. Important other procedures of these parameters determination based on measurement and calculation are explained and reviews of selected insulation resistance measurement devices as well as earth fault locating systems are included. For the text understanding merely basic knowledge of electrical circuits theory is required. This book is addressed to electrical engineers, technicians and students of this specialty and may also serve as an academic handbook. ; PDF; Scientific, Technical and Medical > Energy technology & engineering > Electrical engineering, Springer Berlin Heidelberg<
hive.co.uk
No. 9783642297557. Versandkosten:Instock, Despatched same working day before 3pm, zzgl. Versandkosten. Details...
(*) Derzeit vergriffen bedeutet, dass dieser Titel momentan auf keiner der angeschlossenen Plattform verfügbar ist.
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use… Mehr…
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use are high reliability and numerous advantages offered by isolating them against ground. Insulation level is a decisive factor for networks operational reliability and safety. Insufficient insulation-to-ground resistance can cause various disturbances. Though ground faults in IT systems do not make networks operation impossible, they may cause severe problems with their safe functioning. In this book the most important issues concerning normal operation and ground fault phenomena are described in concise form. Numerous methods of insulation resistance and capacitance measurement in live circuits are presented. Important other procedures of these parameters determination based on measurement and calculation are explained and reviews of selected insulation resistance measurement devices as well as earth fault locating systems are included. For the text understanding merely basic knowledge of electrical circuits theory is required. This book is addressed to electrical engineers, technicians and students of this specialty and may also serve as an academic handbook., Springer<
Springer.com
Nr. 978-3-642-29755-7. Versandkosten:Worldwide free shipping, , DE. (EUR 0.00) Details...
(*) Derzeit vergriffen bedeutet, dass dieser Titel momentan auf keiner der angeschlossenen Plattform verfügbar ist.
This book describes in concise form the most important issues concerning normal operation and ground fault phenomena.The authors present numerous methods of insulation resistance and capa… Mehr…
This book describes in concise form the most important issues concerning normal operation and ground fault phenomena.The authors present numerous methods of insulation resistance and capacitance measurement in live circuits.; PDF; Scientific, Technical and Medical > Energy technology & engineering > Electrical engineering, Springer Japan<
hive.co.uk
No. 9783642297557. Versandkosten:Instock, Despatched same working day before 3pm, zzgl. Versandkosten. Details...
(*) Derzeit vergriffen bedeutet, dass dieser Titel momentan auf keiner der angeschlossenen Plattform verfügbar ist.
Insulation Measurement and Supervision in Live AC and DC Unearthed Systems: ab 96.49 € eBooks > Sachthemen & Ratgeber > Technik Springer-Verlag GmbH eBook als pdf, Springer-Verlag GmbH
eBook.de
Versandkosten:in stock, , , DE. (EUR 0.00) Details...
(*) Derzeit vergriffen bedeutet, dass dieser Titel momentan auf keiner der angeschlossenen Plattform verfügbar ist.
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use… Mehr…
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use are high reliability and numerous advantages offered by isolating them against ground. Insulation level is a decisive factor for networks operational reliability and safety. Insufficient insulation-to-ground resistance can cause various disturbances. Though ground faults in IT systems do not make networks operation impossible, they may cause severe problems with their safe functioning. In this book the most important issues concerning normal operation and ground fault phenomena are described in concise form. Numerous methods of insulation resistance and capacitance measurement in live circuits are presented. Important other procedures of these parameters determination based on measurement and calculation are explained and reviews of selected insulation resistance measurement devices as well as earth fault locating systems are included. For the text understanding merely basic knowledge of electrical circuits theory is required. This book is addressed to electrical engineers, technicians and students of this specialty and may also serve as an academic handbook. ; PDF; Scientific, Technical and Medical > Energy technology & engineering > Electrical engineering, Springer Berlin Heidelberg<
No. 9783642297557. Versandkosten:Instock, Despatched same working day before 3pm, zzgl. Versandkosten.
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use… Mehr…
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use are high reliability and numerous advantages offered by isolating them against ground. Insulation level is a decisive factor for networks operational reliability and safety. Insufficient insulation-to-ground resistance can cause various disturbances. Though ground faults in IT systems do not make networks operation impossible, they may cause severe problems with their safe functioning. In this book the most important issues concerning normal operation and ground fault phenomena are described in concise form. Numerous methods of insulation resistance and capacitance measurement in live circuits are presented. Important other procedures of these parameters determination based on measurement and calculation are explained and reviews of selected insulation resistance measurement devices as well as earth fault locating systems are included. For the text understanding merely basic knowledge of electrical circuits theory is required. This book is addressed to electrical engineers, technicians and students of this specialty and may also serve as an academic handbook., Springer<
Nr. 978-3-642-29755-7. Versandkosten:Worldwide free shipping, , DE. (EUR 0.00)
This book describes in concise form the most important issues concerning normal operation and ground fault phenomena.The authors present numerous methods of insulation resistance and capa… Mehr…
This book describes in concise form the most important issues concerning normal operation and ground fault phenomena.The authors present numerous methods of insulation resistance and capacitance measurement in live circuits.; PDF; Scientific, Technical and Medical > Energy technology & engineering > Electrical engineering, Springer Japan<
No. 9783642297557. Versandkosten:Instock, Despatched same working day before 3pm, zzgl. Versandkosten.
Insulation Measurement and Supervision in Live AC and DC Unearthed Systems: ab 96.49 € eBooks > Sachthemen & Ratgeber > Technik Springer-Verlag GmbH eBook als pdf, Springer-Verlag GmbH
1Da einige Plattformen keine Versandkonditionen übermitteln und diese vom Lieferland, dem Einkaufspreis, dem Gewicht und der Größe des Artikels, einer möglichen Mitgliedschaft der Plattform, einer direkten Lieferung durch die Plattform oder über einen Drittanbieter (Marketplace), etc. abhängig sein können, ist es möglich, dass die von eurobuch angegebenen Versandkosten nicht mit denen der anbietenden Plattform übereinstimmen.
Detailangaben zum Buch - Insulation Measurement and Supervision in Live AC and DC Unearthed Systems
EAN (ISBN-13): 9783642297557 ISBN (ISBN-10): 3642297552 Erscheinungsjahr: 2012 Herausgeber: Springer Berlin 198 Seiten Sprache: eng/Englisch
Buch in der Datenbank seit 2012-01-07T14:04:54+01:00 (Zurich) Detailseite zuletzt geändert am 2024-02-06T17:34:09+01:00 (Zurich) ISBN/EAN: 3642297552
ISBN - alternative Schreibweisen: 3-642-29755-2, 978-3-642-29755-7 Alternative Schreibweisen und verwandte Suchbegriffe: Autor des Buches: pio, fröhlich Titel des Buches: supervision, live system, unearthed, measurement systems
Daten vom Verlag:
Autor/in: Piotr Olszowiec Titel: Lecture Notes in Electrical Engineering; Insulation Measurement and Supervision in Live AC and DC Unearthed Systems Verlag: Springer; Springer Berlin 198 Seiten Erscheinungsjahr: 2012-07-16 Berlin; Heidelberg; DE Sprache: Englisch 96,29 € (DE) 99,00 € (AT) 133,50 CHF (CH) Available X, 198 p. 122 illus.
EA; E107; eBook; Nonbooks, PBS / Technik/Elektronik, Elektrotechnik, Nachrichtentechnik; Elektronik; Verstehen; Electrcial Engineering; Ground Fault Phenomena; Insulation Monitoring in AC and DC IT Systems; B; Electronics and Microelectronics, Instrumentation; Electrical and Electronic Engineering; Engineering; Elektrotechnik; BB
Low voltage unearthed (IT) AC and DC systems are commonly applied for supply of power and control circuits in industry, transportation, medical objects etc. The main reasons for their use are high reliability and numerous advantages offered by isolating them against ground. Insulation level is a decisive factor for networks operational reliability and safety. Insufficient insulation-to-ground resistance can cause various disturbances. Though ground faults in IT systems do not make networks operation impossible, they may cause severe problems with their safe functioning. In this book the most important issues concerning normal operation and ground fault phenomena are described in concise form. Numerous methods of insulation resistance and capacitance measurement in live circuits are presented. Important other procedures of these parameters determination based on measurement and calculation are explained and reviews of selected insulation resistance measurement devices as well as earth fault locating systems are included. For the text understanding merely basic knowledge of electrical circuits theory is required. This book is addressed to electrical engineers, technicians and students of this specialty and may also serve as an academic handbook. Provides insight into important issues concerning AC and DC IT systems incl. a basic theory of operation caused by ground insulation deterioration Presents practical methods of insulation resistance and capacitance measurement in live networks with derivation of formulas Presents commonly used monitoring devices and systems and an explanation of their settings selection